 BROKEN PLUNGER
 

The plunger were broken when assembly the handle.  From the broken parts investigation could infer that there are several reasons to cause the issue:

1. The vender supplied nonconforming components:
 
a. The ID (Inside Diameter) at bottom was beyond the tolerance.
b. Inner face was rough.
c. Unclean chips was found inside bottom of plunger.
2. The "Receiving Inspection" process was inadequate.
To ensure this will not happen again, a quality control meetingthe was called with QC and the vendor, and the DMAIC tool were utilized to improve the process.
    Broken Plunger     a. Inside Bottom     b. Rough IF     c. Unclean Chips
       
Conclusion:
1. The vender should improve their process to ensure the product quality. The suggestion is:
 
a. Make two special gage to measure the ID, for both side.
b. Maintain the machine feeding rate and train their employees.
c. Maintain the proper tool for the cutting process and clean chips.
2. The QC "Receiving Inspection" process must be improved.
3. Train the employees in both manufacturing and QC